Honeywell PUB6438SR/U Controller

Spyder BACNet Programmable Unitary Controller, 6 Universal/4 Digital Inputs,

3 Analog/8 Digital Outputs


Overview

The Spyder Family of controllers are for use in VAV (Variable Air Volume) and Unitary HVAC

control applications. Each controller communicates via either LONWORKS? or BACnet MS/TP

network communications. Each controller provides flexible, universal inputs (UI) for external

sensors, digital inputs (DI), and a combination of analog outputs (AO) and digital Triac outputs

(DO). The Sylk Bus is included in each controller which enables connection to other Sylk enabled

devices. These controllers provide many options and advanced system features that allow

state-of-the-art commercial building control. Each controller is programmable and configurable

using the NIAGARA AX FRAMEWORK software.

Product Specifications

Application

Unitary

Dimensions (in.)

5.45 in. high x 6.85 in. wide x 2.26 in. deep

Dimensions (mm)

138.4 mm high x 174 mm wide x 57.4 mm deep

Comments

Onboard 20 VDC power supply

Frequency

50 Hz; 60 Hz

Approvals, Underwriters Laboratories Inc.

UL 916

Approvals, Canadian Standards Association

Certified

Operating Humidity Range (% RH)

5 to 95% RH, non-condensing

Application Size

Small to Large

I/O Count

6 UI, 4 DI, 3 AO, 8 DO

Output Type

Relay DO's, Staged On/Off

Compatible With

WEBs-AX; WEBs-N4

Power Consumption

5 VA

Voltage

24 Vac with a valid range of 20 to 30 Vac

Setpoint Temperature Range (C)

Programmable

Setpoint Temperature Range (F)

Programmable

Operating Temperature Range (F)

-40 F to 150 F

Operating Temperature Range (C)

-40 C to 65.5 C

Shipping and Storage Temperature Range (F)

-40 F to 150 F

Shipping and Storage Temperature Range (C)

-40 C to 65.5 C

Approvals, Federal Communications Commission

FCC Part 15, Subpart B, Class B

Approvals, CE

Approved

Building Management Interface

WEBs-AX; WEBs-N4

Network Communications

BACnet

Commissioning Software

WEBs-AX; WEBs-N4